Investigación sobre la evaluación cuantitativa de la función tubular renal basada en imágenes dinámicas renales

Read full text
Authors: W. (Wenjuan) Liu, G. Yao, Y. Gao, C. Wang
Cited by: 0
References: 15

Abstract

Establecer un modelo de tasa de reabsorción tubular renal (RTUR) basado en imágenes dinámicas renales (RDI) para detectar lesiones tubulares tempranas y explorar su valor de aplicación clínica. Se analizaron los datos de RDI recopilados entre agosto de 2020 y junio de 2025. Se incluyeron un total de 292 casos elegibles (441 riñones). Los participantes se clasificaron en: - Grupo de control: 56 casos (112 riñones) - Grupo con insuficiencia renal: 93 casos (186 riñones) - Grupo totalmente compensado: 62 casos (62 riñones) - Grupo parcialmente compensado: 35 casos (35 riñones) - Grupo descompensado: 46 casos (46 riñones) RTUR = (pendiente ascendente de la gammagrafía renal/actividad total del fármaco radiactivo inyectado) × 10 5 × 100%. Distribución de los valores de RTUR en los cinco grupos; correlación entre la tasa de filtración glomerular (TFG) y la RTUR en 441 riñones. Diferencias en la RTUR entre el grupo de control y los otros cuatro grupos; eficacia diagnóstica y valor clínico de la RTUR. En comparación con el grupo de control, se observaron diferencias significativas en el RTUR en el grupo con insuficiencia renal, el grupo con compensación completa y el grupo descompensado (p < 0,01). La TFG en 441 riñones mostró una fuerte correlación positiva con el RTUR (r = 0,739, p < 0,001). El análisis ROC indicó que una RTUR ≤ 5.225% identificaba la insuficiencia renal (sensibilidad del 77,7%, especificidad del 70,4%), mientras que una RTUR ≥ 9.135% diagnosticaba una compensación renal completa con una sensibilidad del 82,3%. El modelo RTUR permite una evaluación cuantitativa estable de la tasa de reabsorción tubular renal, lo que facilita el diagnóstico de insuficiencia renal y compensación renal completa. Es prometedor como nuevo indicador cuantitativo para evaluar la función tubular. La TFG renal muestra una fuerte correlación con la RTUR. To establish a renal tubular uptake rate (RTUR) model based on renal dynamic imaging (RDI) for detecting early tubular injury and to explore its clinical application value. RDI data collected from August 2020 to June 2025 were analyzed. A total of 292 eligible cases (441 kidneys) were included. Participants were categorized into:-Control group: 56 cases (112 kidneys)-Renal insufficiency group: 93 cases (186 kidneys)-Fully compensated group: 62 cases (62 kidneys)-Partially compensated group: 35 cases (35 kidneys)-Decompensated group: 46 cases (46 kidneys) RTUR = (Ascent slope of renal scintigraphy / Total injected radioactive drug activity) × 10 5 × 100%. Distribution of RTUR values across five groups; correlation between GFR and RTUR in 441 kidneys. Differences in RTUR between the control group and other four groups; diagnostic efficacy and clinical value of RTUR. Compared with the control group, significant differences in RTUR were observed in the renal insufficiency group, fully compensated group, and decompensated group (P < 0.01). GFR in 441 kidneys showed a strong positive correlation with RTUR (r = 0.739, P < 0.001). ROC analysis indicated that RTUR ≤ 5.225% identified renal insufficiency (sensitivity 77.7%, specificity 70.4%), while RTUR ≥ 9.135% diagnosed complete renal compensation with 82.3% sensitivity. The RTUR model enables stable quantitative assessment of renal tubular reabsorption rate, facilitating diagnosis of renal insufficiency and complete renal compensation. It holds promise as a novel quantitative indicator for evaluating tubular function. Renal GFR exhibits a strong correlation with RTUR.

Fields of Study & Subjects

Chronic Kidney Disease and Diabetes Medical Imaging Techniques and Applications Acute Kidney Injury Research

Publication details

Journal / source
Revista Española de Medicina Nuclear e Imagen Molecular
Volume
45
Issue
3
Pages
500268–500268
Publication date
27 February 2026
Language
ES