Advanced conceptual design for the regasification process to minimize carbon emissions, water use, and reduce operating costs for AI data centers, airport hubs, smart cities and initial zero-emission LNG receiving terminals

Read full text
Authors: Maytungkorn Sermsuk, Yanin Sukjai, Srithar Rajoo, Kunlanan Kiatkittipong, Montri Wiboonrat, Surapong Siripongdee
Cited by: 1
References: 43

Abstract

An advanced LNG regasification system integrating IFV, RC, and DEC is developed LNG waste cold energy is converted into electricity and large-scale chilled water The system supports multi-pressure gas delivery at 70, 30, and 6 bar Up to 100% of LNG cold energy is utilized for power generation and district cooling Significant reductions in electricity use, carbon emissions, and operating cost are achieved Achieving net-zero greenhouse gas emissions by 2050 requires improving energy efficiency in transitional fuels such as liquefied natural gas (LNG). In 2023, global LNG imports reached 401.5 MTPA; however, most of the 180 LNG receiving terminals worldwide still discharge large amounts of recoverable cold energy into the ocean. Meanwhile, rapid growth of artificial intelligence (AI) data centers is driving unprecedented electricity demand, with projected global consumption exceeding 3000 TWh by 2030. This study proposes an advanced LNG regasification system integrating Intermediate Fluid Vaporization (IFV), Rankine Cycle (RC), and Direct Expansion Cycle (DEC) to recover both temperature and pressure exergy. The system is evaluated for LNG terminals with capacities of 10–30 MTPA under pressure levels of 70, 30, and 6 bar across eight operational models and two infrastructure configurations. Results indicate that terminal electricity imports are reduced by 52–78% compared with conventional open rack vaporizer (ORV) systems. Net electricity generation ranges from 12.09 to 197.91 MW, while chilled water cooling capacity reaches 272.72–1075.44 MW. Cooling electricity demand is reduced by approximately 79%, lowering data center Power Usage Effectiveness (PUE) from 2.00 to 1.36. Water Usage Effectiveness (WUE) decreases from 1.9–3.0 to approximately 0.3 L/kWh, achieving an 89–93% reduction in cooling-related water use. At 30 MTPA, carbon emissions are reduced by up to 2.99 million tons annually, with economic savings of USD 119.96–603.15 million per year and a maximum IRR of 37.7%. These results demonstrate the significant potential of LNG cold energy integration for near-zero-emission terminal operation and sustainable data center cooling.

Fields of Study & Subjects

Thermodynamic and Exergetic Analyses of Power and Cooling Systems Integrated Energy Systems Optimization Solar Thermal and Photovoltaic Systems

Publication details

Journal / source
Results in Engineering
Publisher
Elsevier BV
Volume
30
Pages
111031–111031
Publication date
15 May 2026
Language
EN