Comparison of FE-based DVC and Integrated DVC for LEFM parameter calibration

Read full text
Authors: Malo Valmalle, Benjamin Smaniotto, François Hild
Cited by: 2
References: 49

Abstract

In the present work, the mechanical response of a 3D printed CT specimen made of Polycarbonate was studied when subjected to an opening loading. Kinematic fields were first measured via Finite Element based Digital Volume Correlation (FE-based DVC) and then via Integrated DVC (I-DVC) using Williams’ series as measurement basis. Linear Elastic Fracture Mechanics parameters were extracted from the measured FE-based DVC displacement fields using William’s series and directly within the I-DVC procedure. Both procedures were then compared against each other. I-DVC proved to be more accurate as well as computationally less intensive. The impact of the choice of the regularization length on LEFM parameters measurement accuracy was also assessed.

Fields of Study & Subjects

Advanced Electrical Measurement Techniques Microwave and Dielectric Measurement Techniques Advanced Fiber Optic Sensors

Publication details

Journal / source
Theoretical and Applied Fracture Mechanics
Publisher
Elsevier BV
Volume
144
Pages
105561–105561
Publication date
6 March 2026
Language