Influence of open circuit potential time on the corrosion behavior of heat treated AZ80 magnesium alloy

Read full text
Authors: Ján Sovík, Stefan Gneiger, Nikolaus Papenberg, Daniel Kajánek, Branislav Hadzima
Cited by: 1
References: 5

Abstract

The main aim of the paper is to provide findings about the influence of open circuit potential (OCP) time on the corrosion behavior of heat treated AZ80 magnesium alloy in an aggressive chloride environment. Corrosion characteristics of the as-cast, as-extruded and exruded + heat treated state were obtained by potentiodynamic polarization tests (PDP) at the laboratory temperature in 0.1 M NaCl solution. Additionally, a study of the microstructure was carried out using optical microscopy and the analysis of individual phases was performed by thermodynamic calculations in the equilibrium state. Longer OCP time leads to the formation of a passive layer that improves corrosion resistance of the substrate.

Fields of Study & Subjects

Magnesium Alloys: Properties and Applications Corrosion Behavior and Inhibition Aluminum Alloy Microstructure Properties

Publication details

Journal / source
Transportation research procedia
Publisher
Elsevier BV
Volume
93
Pages
407–412
Publication date
1 January 2026
Language