Ultrasonic treatment effects on hydroxyl radical generation in various solution systems: an iodometric analysis

Read full text
Authors: Yuanfang Liu, Yuanxiao Liu, Yuanxiao Liu, Minghui Liu, Hailu Hou, Minghui Liu, Ying-Ying Li, Jinming Xu, Jiayu Guo
Cited by: 1
References: 28

Abstract

Hydroxyl radicals (•OH) are key reactive species in sonochemical processes; however, their generation is strongly dependent on the operating parameters and solution composition. In this study, probe-ultrasonication-induced oxidizing response was evaluated using an iodometric method in a 0.4mol L −1 KI background, where the measured response reflects the accumulated titratable iodine (I 3 - ) signal and is therefore discussed as an apparent •OH yield rather than an instantaneous steady-state [•OH]. The effects of sonication time (5–35 min), ultrasonic power (60–300 W), duty cycle (20%–100%), and probe position (top/middle/bottom) were systematically investigated. The apparent •OH yield increased with time and power, reached a maximum at a duty cycle of 60%, and was highest when the probe was positioned at the center of the liquid column. The influence of solution composition was further evaluated by adding ethanol, acetic acid, NaOH, NaHCO 3 , and NaCl to the KI background. Increasing the ethanol and NaOH concentrations generally decreased the apparent •OH yield, whereas acetic acid showed a biphasic response. NaHCO 3 decreased the apparent •OH yield in a concentration-dependent manner, and NaCl showed a non-monotonic concentration dependence. In phosphotungstic acid systems, the iodometric response increased with concentration at 10 min but the concentration dependence diminished at 30 min, and a no-ultrasound control showed a measurable baseline signal while ultrasound produced a stronger response. Hydrogen peroxide markedly enhanced the response at moderate concentration but reduced the apparent •OH yield at higher levels due to competing reactions, while a t-BuOH scavenger control reduced the signal to about 10% of that without t-BuOH, indicating predominantly •OH-driven response with minor non-specific contributions. These results provide practical guidance for regulating the accumulated oxidative response in probe-ultrasonic systems

Fields of Study & Subjects

Ultrasound and Cavitation Phenomena Advanced oxidation water treatment Electron Spin Resonance Studies

Publication details

Journal / source
Ultrasonics Sonochemistry
Publisher
Elsevier BV
Volume
131
Pages
107917–107917
Publication date
9 June 2026
Language
EN