Automated Nonperfusion Quantification in Diabetic Retinopathy on Ultra-Widefield Swept-Source OCT Angiography

Read full text
Authors: Tai Yong Loh, Juling Sia, Wei Hing Seah, Lingyi Zhuang, Wenjun Song, Yue Qiu, Xiaofeng Shen, Zhongqing Yu, Ryan Tan, Nuo Tang, Yusra Asad, Colin Ming Hui Goh
+11 more Charmayne Xinyi Ang, Celyn Chng, Peiqi Lo, Pavan Paniharam, Ser Koon Goh, Hnin Hnin Oo, Min Wang, Rupesh Agrawal, Nicola Yi An Gan, Yali Jia, Sandy Wenting Zhou
Cited by: 4
References: 38

Abstract

To evaluate the performance of a customized deep learning algorithm for automated segmentation of nonperfusion area (NPA) on ultrawide-field swept-source optical coherence tomography angiography (UWF SS-OCTA) and its utility in diabetic retinopathy (DR) severity assessment. Design Cross-sectional study SubjectsA total of 180 eyes from 122 participants representing all grades of DR severity. MethodsWe developed a convolutional neural network (CNN) based on a multi-scale U-Net backbone with squeeze-and-excitation attention for segmentation of NPAs on en face SS-OCTA all-retinal-layer (ARL) images from three scan patterns: 6 × 6 mm, 12 × 12 mm, and 29 × 24 mm.Ground truth annotations of NPAs and non-gradable area (NGA) on en face OCTA images were generated by two independent graders and adjudicated by a vitreoretinal specialist.A corresponding en face structural OCT was incorporated to distinguish true NPAs from shadow artifacts.Segmentation outputs included NPA, NGA and shadow artifacts.Pixel-level accuracy was assessed with the F1 score.Nonperfusion index (NPI) was defined as NPA/gradable area.The level of agreement between human-labelled and AI predicted NPI was analyzed using Bland-Altman analysis. J o u r n a l P r e -p r o o f Main Outcome MeasuresAlgorithm F1 score and NPI. ResultsThe algorithm for NPA segmentation achieved a mean F1 score of 0.82 ± 0.01 in 6 × 6 mm, 0.84 ± 0.03 in 12 × 12mm and 0.83 ± 0.02 in 29 × 24mm, with no significant difference across fields of view (p = 0.12).Algorithm-derived NPI strongly agreed with expert grading (ICC > 0.99).Both human-and algorithm-derived NPI increased progressively with increased DR severity in all scan patterns demonstrated by the Kruskal-Wallis test.(6 × 6 mm: human: p = 0.02; algorithm: p = 0.03; 12 × 12 mm: algorithm p < 0.001; human p < 0.001; 29 × 24 mm: algorithm:p < 0.001; human:p < 0.001) with the largest magnitude of increase in 29 × 24 mm scans.The algorithm for FAZ segmentation also achieved a mean F1 score of 0.88 ± 0.03 for 6 x 6 mm images and 0.85 ± 0.02 for 12 x 12 mm images. ConclusionThis deep learning algorithm validated on single-scan UWF SS-OCTA for automated NPA segmentation and quantification.It demonstrates high accuracy and scalability across multiple scan sizes, supporting its potential integration into objective DR OCTA biomarker analysis.

Fields of Study & Subjects

Retinal Diseases and Treatments Retinal Imaging and Analysis Optical Coherence Tomography Applications

Publication details

Journal / source
Ophthalmology Science
Publisher
Elsevier BV
Volume
6
Issue
3
Pages
101059–101059
Publication date
5 January 2026
Language