Setup reproducibility of the semi-Fowler’s position in radiotherapy: a practical feasibility study

Read full text
Authors: Seungwon Park, Taegyu Kim, J O Choi, 정천영, Sanghoo Park, Junho Cho, Haemin Lim, Jinsik Kim
Cited by: 1
References: 7

Abstract

Abstract Objectives: To evaluate the setup reproducibility of the semi-Fowler’s position as a practical positioning strategy for radiotherapy patients who are unable to tolerate standard supine or prone positioning. Materials and Methods: Fifteen patients with respiratory or musculoskeletal limitations preventing standard positioning were retrospectively analysed. All patients were treated in the semi-Fowler’s position using routinely available immobilisation components. Setup reproducibility was assessed using orthogonal kilovoltage (kV) imaging with two-dimensional image matching. Translational displacements along the lateral (X), longitudinal (Y) and vertical (Z) axes were evaluated using the intraclass correlation coefficient, Lin’s concordance correlation coefficient and Bland–Altman analysis. Results: Median setup errors across all translational directions were close to zero, with the majority of displacements remaining within ±0.5 cm. Bland–Altman analysis demonstrated acceptable agreement across repeated fractions. Slightly increased variability was observed along the longitudinal and vertical axes, consistent with gravitational effects associated with semi-inclined positioning. Conclusions: The semi-Fowler’s position can be implemented as a practical and reproducible positioning option for selected radiotherapy patients when standard setups are not tolerated, without compromising geometric accuracy under routine image guidance.

Fields of Study & Subjects

Advanced Radiotherapy Techniques Lung Cancer Diagnosis and Treatment Hepatocellular Carcinoma Treatment and Prognosis

Publication details

Journal / source
Journal of Radiotherapy in Practice
Publisher
Cambridge University Press (CUP)
Volume
25
Publication date
1 January 2026
Language
EN