Crossflow CO 2 Absorber Design for Gas-Fired Combined Cycles

View at publisher
Authors: Miguel Abreu, Gary Thomas Rochelle
Cited by: 1
References: 16

Abstract

Crossflow CO 2 absorbers were designed for a 110 MW Natural Gas Combined Cycle power plant with a height limitation of 7 m. Five molal piperazine (PZ) (30 wt %) was simulated in Aspen Plus with a lean solvent loading of 0.2 mol CO 2 /equiv N at 90% CO 2 removal. A simple absorber and an absorber with pump-around intercooling were modeled. All configurations used a crossflow water wash to maintain the water balance around the absorber. Sulzer MellapakPlus 252Y structured packing was used. All crossflow configurations underperformed compared to analogous countercurrent designs. An analysis of the interfacial temperature and CO 2 flux profiles showed that crossflow absorbers developed multiple mass transfer pinches and CO 2 stripping by the flue gas, despite the relatively low temperature. These represent a fundamental shortcoming unique to the crossflow absorber. If performance costs can be tolerated, crossflow can be attractive alternative to countercurrent units when height constraints are present.

Fields of Study & Subjects

Carbon Dioxide Capture Technologies Thermodynamic and Exergetic Analyses of Power and Cooling Systems Phase Equilibria and Thermodynamics

Publication details

Journal / source
Industrial & Engineering Chemistry Research
Publisher
American Chemical Society (ACS)
Volume
65
Issue
4
Pages
2288–2302
Publication date
26 January 2026
Language
EN