The Use of Glycine-Containing Peptide-Based Chelators for Labeling with 99m Tc Improves the Imaging Properties of EpCAM-Targeting Designed Ankyrin Repeat Ec1

View at publisher
Authors: Sergey M. Deyev, A.S. Fominykh, Ruslan Varvashenya, Gleb Yanovich, Vitalina Bodenko, Evgenii Plotnikov, Mariia S. Tretyakova, Daria D. Eskova, Roman Zhelchan, Alexey A. Schulga, E. N. Konovalova, Rustam H. Ziganshin
+4 more Anna Orlova, Mikhail Belousov, Vladimir Tolmachev, Mariia Larkina
Cited by: 2
References: 47

Abstract

Noninvasive radionuclide imaging of epithelial cell adhesion molecule (EpCAM) expression in lung, ovarian, breast, kidney, and other cancers can stratify patients for EpCAM-targeted therapy. The constructed scaffold proteins, designed ankyrin repeat proteins (DARPins), are highly specific high-affinity probes for radionuclide imaging. A clinical study demonstrated that the anti-EpCAM DARPin [ 99m Tc]Tc-(HE) 3 -Ec1 showed precise EpCAM imaging at 2, 4, and 6 h after injection in patients with nonsmall cell lung cancer. However, a noticeable accumulation in healthy organs has prompted the development of new Ec1-based agents with improved biodistribution properties. In addition, it would be desirable to substitute a labor-intensive labeling procedure. The purpose of this study was to test the hypothesis that the use of Gly-Gly-Gly-Cys (G 3 C) or Glu-Glu-Glu-Cys (E 3 C) peptide chelators placed at the C-terminus of DARPin for labeling with 99m Tc (V) could improve the image contrast and biodistribution of Ec1. The radiochemical yield of the new variants exceeded 95%. The labeled proteins specifically bound to human EpCAM-expressing cancer cell lines with affinities of 8–10 nM. The biodistribution of [ 99m Tc]Tc-Ec1-G 3 C and [ 99m Tc]Tc-Ec1-E 3 C in mice was compared with the biodistribution of clinically tested [ 99m Tc]Tc-(HE) 3 -Ec1 in a Nu/j mouse model with SKOV-3 xenografts. The new variants specifically accumulate in human xenografts with EpCAM expression. The accumulation of new variants in healthy organs (liver, salivary glands, spleen, and stomach) was reduced compared to [ 99m Tc]Tc-(HE) 3 -Ec1. [ 99m Tc]Tc-Ec1-G 3 C provided the best imaging contrast and is suitable for clinical testing.

Fields of Study & Subjects

Radiopharmaceutical Chemistry and Applications Lanthanide and Transition Metal Complexes Cell Adhesion Molecules Research

Publication details

Journal / source
Molecular Pharmaceutics
Publisher
American Chemical Society (ACS)
Volume
23
Issue
4
Pages
2469–2480
Publication date
4 March 2026
Language
EN