Bioinspired Hydrogel-Functionalized Microchannel-Gated Junction Field-Effect Transistor for Highly Sensitive Glutathione Detection

View at publisher Summarise with VIRAT
Authors: Yulan Zeng, Sijia Yu, Huabin Cai, Weixin Li, Yanling Huang, Juanjuan Chen, Jian Wang, Fengfu Fu, Zhonghui Chen, Zhenyu Lin
Cited by: 0
References: 49

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Inspired by the gating behavior of biological ion channels, microchannel-based sensing has emerged as an effective strategy for regulating ionic transport through charge density and pore size modulation. Field-effect transistor (FET)-based biosensors have received considerable attention owing to their high sensitivity to subtle charge variations. In this study, this character had been coupled with the junction field-effect transistor (JFET) detection technique to develop a sensitive biosensor for glutathione (GSH). A hydrogel was formed by Schiff-base crosslinking between aldehyde-modified hyaluronic acid (AHA) and 3-[(3-hydrazinyl-3-oxopropyl)disulfanyl] propanehydrazide (DTP) and subsequently confined within the microchannel, which served as a tunable resistor positioned between the gate and source of the JFET. Variations in the microchannel resistance induce a voltage division effect, thereby modulating the distribution of the effective gate voltage, which changes the channel current. Upon the presence of GSH, disulfide bonds of DTP within the hydrogel were reduced, generating thiol groups and disrupting the hydrogel network, which enlarged the pore size and increased the negative charge density. These changes reduced the microchannel resistance and increased the effective negative gate voltage, leading to a significant reduction of the channel current. The biosensor exhibited excellent sensitivity and selectivity toward GSH with a linear range from 100 nM to 1.00 mM, and the detection limit was 38.1 nM, along with good recovery and reproducibility in diluted human serum samples. This sensor provides a novel strategy for highly sensitive GSH detection and holds potential as a versatile platform for clinical diagnostics and disease monitoring.

Fields of Study & Subjects

Analytical Chemistry and Sensors Electrochemical sensors and biosensors Sulfur Compounds in Biology

Publication details

Journal / source
ACS Sensors
Volume
11
Issue
4
Pages
3297–3308
Publication date
20 March 2026
Language
EN