Bioequivalence assessment between two formulations of a film-coated fixed-dose combination of metformin and vildagliptin (850/50mg) in healthy Tunisian subjects under fed conditions

Read full text
Authors: Khouloud Ferchichi, Emna Gaïes, Syrine Ben Hammamia, Hanène El Jebari, Mouna Daldoul, Salma Ghorbel, Semia Srairi, Sami Guermazi, Yousr Lakhoua Gorgi, Ilhem Boutiba, Kahena Bouzid, Aimen Abbessi
+3 more R. Daghfous, Mouna Ben Sassi, Sameh Trabelsi
Cited by: 0
References: 7

Abstract

Abstract In Tunisia, bioequivalence studies have been required for generic drug approval since 2008. This study aimed to assess the bioequivalence of vildagliptin and metformin fixed-dose combination (FDC) 850/50 mg for a tested (Bi-Galvine) versus the approved reference products (Galvumet). A randomized, two-way, two-period, single oral dose, open-label, crossover, bioequivalence study with a washout period of 7 days to compare metformin/vildagliptin film-coated tablets in 18 healthy Tunisian subjects aged between 18 and 50 years under fed conditions was conducted at the National Center Chalbi Belkahia of Pharmacovigilance. During each period, 20 blood samples were collected from each subject at pre-dosing (0.00) and between 0.25 and 24.00 h after dosing. The bioequivalence between the test (T) and reference (R) products required 90% confidence intervals (CIs) for the geometric least square (LS) mean T/R ratio to be within 80–125% for the pharmacokinetic parameters, maximum plasma concentration (C max ), and Area Under the Curve from zero to 24 h (AUC 0–24 h ). The 90% CIs of the geometric means of the T/R ratios for C max and AUC 0–24 h for metformin were 92.01–102.66% and 93.55–101.80%, respectively; the corresponding results for vildagliptin were 96.03–107.09% and 94.46–101.92%, respectively. Other parameters, such as AUC 0-∞ , time to maximum concentration (T max ), and terminal half-life (t 1/2 ), were comparable between the test and reference products. Adverse events (AEs), mainly hypoglycemia and loose stools events, were reported without relevant differences between the test and reference products. AEs were generally mild and transient. No severe or serious AEs occurred. The new generic drug product of metformin/vildagliptin FDC 850/50 mg demonstrated bioequivalence to the approved product and is therefore expected to provide similar therapeutic effects.

Fields of Study & Subjects

Diabetes Treatment and Management Statistical Methods in Clinical Trials Pharmaceutical studies and practices

Publication details

Journal / source
Scientific Reports
Volume
16
Issue
1
Pages
5407–5407
Publication date
6 February 2026