Differences of anterior segment features in fellow eyes of primary angle closure glaucoma and healthy eyes

Read full text
Authors: Liang Guo, Yan Wu, Na Wang, Qingyi Liu, Zhimin Shen, Lu Yang
Cited by: 0
References: 27

Abstract

To compare healthy eyes to the fellow eyes of acute primary angle closure (F-APAC), healthy eyes to the fellow eyes of chronic primary angle closure glaucoma (F-CPACG), and these fellow eyes to each other (F-APAC vs. F-CPACG). This study included patients with PACG (72 eyes) and healthy individuals (22 eyes). Parameters were measured on ultrasound biomicroscopy images, including anterior chamber depth (ACD), anterior chamber width (ACW), anterior chamber area (ACA), lens vault (LV), relative position lens vault (RPLV), anterior segment depth (ASD), angle opening distance at 500 μm (AOD 500 ), trabecular iris space area at 500 μm (TISA 500 ), trabecular iris angle at 500 μm (TIA 500 ), iris thickness at 500 μm (IT 500 ), peripheral iris thickness maximum (PIT MAX ), iris curvature (IC). Multivariate logistic regression analysis was performed to determine the most important parameters associated with F-APAC compared with F-CPACG. In total, 94 eyes of 94 patients were included. The ACD( P < 0.001), ACW( P < 0.018), ACA( P < 0.001), ASD( P = 0.006), AOD 500 ( P < 0.001), TIA 500 ( P < 0.001) and TISA 500 ( P < 0.001) of the F-APAC were smaller than the healthy, and LV( P < 0.001), RPLV( P < 0.001), IC( P < 0.001) were larger than that. The ACD( P < 0.001), ACA( P < 0.001), ASD( P < 0.001), AOD 500 ( P < 0.001), TISA 500 ( P < 0.001) and TIA 500 ( P < 0.001) of the F-CPACG were smaller than the healthy, and the LV( P < 0.001), RPLV( P < 0.001), PIT MAX ( P = 0.030), IC( P < 0.001) were larger than that. The LV( P = 0.027), AOD 500 ( P = 0.013), TISA 500 ( P = 0.03), TIA 500 ( P = 0.006), IC( P = 0.48) of F-APAC were larger than F-CPACG, and PIT MAX ( P = 0.037) was smaller than F-CPACG. Multivariate logistic regression showed that only larger LV was significantly associated with APAC( P = 0.017). LV (AUC, 0.643) performed relatively in distinguishing the F-APAC and the F-CPACG. Anterior shift of the lens and iris bombe promoted the occurrence of APAC, thickening of the peripheral iris played vital roles in CPACG. Additionally, the LV was an important parameter to distinguish APAC or CPACG.

Fields of Study & Subjects

Glaucoma and retinal disorders Corneal surgery and disorders Intraocular Surgery and Lenses

Publication details

Journal / source
Scientific Reports
Volume
16
Issue
1
Pages
5135–5135
Publication date
13 January 2026
Language
EN