In vitro cytotoxic assessment of a wire arc additively manufactured NiTi wall for biomedical applications

Read full text
Authors: M Kaviya, M Vignesh, Sahil Gaba
Cited by: 1
References: 38

Abstract

In this study, a NiTi wall was fabricated using wire arc additive manufacturing (WAAM), and its in vitro cytotoxicity was systematically evaluated to assess the suitability of WAAM for processing a biocompatible NiTi alloy. Cytotoxicity testing using the MTT assay on HaCaT cells showed high cell viability of 94.08% and 95.77% at the highest extract concentration, confirming the extracts as non-cytotoxic. XRD analysis revealed retention of the predominant B2 austenitic phase with minor B19′ martensite. SEM-EDX and EBSD analyses confirmed a dense and compositionally uniform microstructure with a preferred crystallographic texture along the build direction. Microhardness increased from 288.5 to 373.5 HV along the build height, indicating a stable mechanical response. XPS confirmed the formation of a TiO 2 surface layer, while wettability measurements indicated hydrophilic behaviour. These results confirm that WAAM enables stable fabrication of NiTi while retaining its biological response, demonstrating its suitability for biomedical-related applications.

Fields of Study & Subjects

Shape Memory Alloy Transformations Additive Manufacturing Materials and Processes Titanium Alloys Microstructure and Properties

Publication details

Journal / source
Scientific Reports
Publisher
Springer Science and Business Media LLC
Volume
16
Issue
1
Publication date
6 May 2026
Language
EN