Human-in-the-loop validation of a sequential multi-LLM medical education pipeline

Read full text
Authors: Yoojin Nam, Taein An, Sung Il Hwang, Chawoong Jeon, Ji Won Jeong, Juhyun Jeong, Dong Yeong Kim, Pyeong Hwa Kim, So Yeon Kim, Sungkwan Kim, Yangwon Kim, Kwang Hwi Lee
+9 more T Lee, Hee Sang Oh, Joon Hyung Park, S M Shin, Yongsik Sim, Jeongah Song, Seunghyun Song, Pa Hong, Namkug Kim
Cited by: 1

Abstract

Large language models (LLMs) can generate medical educational content at scale, but multi-dimensional human validation of multi-LLM pipelines has not been performed at scale. We evaluated a 7-stage sequential multi-LLM pipeline implemented exclusively with the Gemini family (Gemini 3 Flash and Pro for text; Gemini 3 Pro Image, the Nano Banana Pro preview, for images), producing 6000 flashcards and 833 infographics for radiology board preparation. Nine residents and eleven attending radiologists evaluated 1284 flashcards across 11 subspecialties in a two-phase design around fifth-stage (S5) feedback. Among 1100 evaluations of 980 text-level PASS cards, the evaluation-level false-negative rate (FNR) for blocking errors was 1.00% (95% CI 0.50-1.78%), exceeding the pre-specified 0.3% safety threshold; card-level (1.12%) and majority-vote (0.82%) analyses converged. S5 feedback was associated with increased blocking-error flags (39-54 evaluation-level observations, McNemar p = 0.003) and decreased technical accuracy and educational quality scores (both p < 0.001). In unadjusted analyses, attending radiologists identified more errors than residents (odds ratio 4.52, 95% CI 2.38-8.57), although workload-matched sensitivity analyses attenuated this gap. A preliminary image pilot of 19 items showed critical errors in both tables and infographics, with between-format comparisons underpowered and not significant after Holm correction; this image-related observation should be interpreted as exploratory. The conditional safety estimates, low-reliability reference standard, and rater- and workload-dependent patterns do not support fully automated deployment; automated feedback was associated with sharpened evaluator scrutiny, though the single-arm design cannot isolate useful cueing from anchoring or re-review effects.

Fields of Study & Subjects

Radiology practices and education Artificial Intelligence in Healthcare and Education AI in cancer detection

Publication details

Journal / source
npj Digital Medicine
Publisher
Springer Science and Business Media LLC
Publication date
7 July 2026
Language
EN