Biofilm development, dynamics, and control in a pilot drinking water network with different pipe materials

Read full text
Authors: Noora Salonen, Kalle Salonen, Marko Suokas, Martti Latva
Cited by: 0
References: 55

Abstract

In this pilot-scale study, biofilm levels were higher in PEX pipes than in metal pipes. Hydrodynamic cavitation and magnetic water treatment had varying effects on PEX biofilm levels, which also correlated with seasonal changes in water temperature.

Fields of Study & Subjects

Water Systems and Optimization Water Treatment and Disinfection Bacterial biofilms and quorum sensing

Publication details

Journal / source
Environmental Science Water Research & Technology
Volume
12
Issue
4
Pages
1264–1279
Publication date
1 January 2026