Selenium oxide nanostructure-based electrodes for rapid and simultaneous electrochemical determination of oxalic and ascorbic acids in food matrices
Abstract
NS-modified electrode exhibited wide linear response ranges of 5.0-550 µM for OA and 5.0-455 µM for AA, with low detection limits of 0.50 µM and 0.43 µM, respectively. The sensor demonstrated remarkable selectivity and stability against common interfering species, ensuring accurate quantification in real samples. Thus, the developed platform was successfully applied to the simultaneous determination of AA and OA in fresh fruits and vegetables (guava, spinach, and mango) and in beverages derived from coffee beans and tea leaves. This work highlights the potential of selenium oxide nanostructures as efficient electroactive materials for high-performance, cost-effective, and reliable electrochemical sensing in food-quality monitoring and safety assessment.
Fields of Study & Subjects
Electrochemical sensors and biosensors
Electrochemical Analysis and Applications
Analytical Chemistry and Sensors
Publication details
- Journal / source
- Nanoscale
- Volume
- 18
- Issue
- 9
- Pages
- 4937–4949
- Publication date
- 1 January 2026
- Language
- EN