A tunable 50 MHz acoustic vortex tweezer for size-selective manipulation and cell pre-concentration

View at publisher
Authors: Xiongwei Wei, Xin Wang, lili miao, Yi Quan, Chunlong Fei, Yintang Yang
Cited by: 1
References: 32

Abstract

= 1, 3, 5) to adjust the capture orbit diameter, ranging from 50 to 150 μm. Manufactured using deep reactive ion etching (DRIE) on monocrystalline silicon, the metasurface ensures lower energy loss and higher structural resolution compared to traditional polymer vortex devices. We demonstrate its multiple application modes: orbital rotation and size-selective manipulation of microparticles, as well as customized range pre-concentration of cells. This device creates a "protective cage" with a low-pressure core that has a variable range, allowing cells to aggregate into clusters. This silicon-based vortex platform is compatible with semiconductor processes, providing a universal label-free solution for biological sample analysis and high-sensitivity downstream detection in lab-on-a-chip systems.

Fields of Study & Subjects

Microfluidic and Bio-sensing Technologies Ultrasound and Hyperthermia Applications Microfluidic and Capillary Electrophoresis Applications

Publication details

Journal / source
Lab on a Chip
Publisher
Royal Society of Chemistry (RSC)
Volume
26
Issue
10
Pages
3184–3191
Publication date
1 January 2026
Language