: methodology for derivation of IPC-corrected conversion gain of nonlinear CMOS APS

View at publisher
Authors: J Le Graet, Aurelia Secroun, Marie Tourneur-Silvain, William Gillard, Nicolas Fourmanoit, S. Escoffier, E. Kajfasz, Smaïn Kermiche, Bogna Kubik, Julien Zoubian, Stefano Andreon, M. Baldi
+88 more S. Bardelli, P. Battaglia, D. Bonino, E. Branchini, M. Brescia, J. Brinchmann, Amandine Caillat, S. Camera, V. Capobianco, C. Carbone, J. Carretero, Santiago Casas, M. Castellano, G. Castignani, S. Cavuoti, G. Congedo, C Colodro-Conde, G. Congedo, Christopher J. Conselice, L. Conversi, Y. Copin, F. Courbin, Hélène M. Courtois, A. Da Silva, J. Dinis, Marian Douspis, F. Dubath, C. A. J. Duncan, Xavier Dupac, S. Dusini, A. Ealet, Maria Farina, S. Farrens, F Faustini, S Ferriol, M. Frailis, Enrico Franceschi, Samuele Galeotta, Bryan R. Gillis, C. Giocoli, Frank U. Grupp, S. V. H. Haugan, W. Holmes, F. Hormuth, A. Hornstrup, Patrick Hudelot, K. Jahnkę, M. Jhabvala, A. Kiessling, M. Kilbinger, R. Kohley, Hannu Kurki-Suonio, Per Barth Lilje, V. Lindholm, Ivan Lloro, Gabriele Mainetti, Davide Maino, E. Maiorano, O. Mansutti, O. Marggraf, Katarina Markovic, N. Martinet, F. Marulli, R. Massey, Eduardo Medinaceli, S. Mei, Massimo Meneghetti, G. Meylan, M. Moresco, Lauro Moscardini, S.-M Niemi, J.W. Nightingale, C. Padilla Aranda, S. Paltani, FABIO PASIAN, K. Pedersen, V. Pettorino, S. Pires, Gianluca Polenta, Maurice Poncet, Lucia Aurelia Popa, Frederic Raison, Alessandro Renzi, J. Rhodes, G. Riccio, E. Romelli, Mauro Roncarelli, E. Rossetti
Cited by: 0

Abstract

We introduce a fast method to measure the conversion gain in complementary metal-oxide-semiconductor active pixel sensors, which accounts for nonlinearity and interpixel capacitance (IPC). The standard “mean-variance” method is biased because it assumes that pixel values depend linearly on the signal, and existing methods to correct for nonlinearity still introduce significant biases. While current IPC correction methods are prohibitively slow for a per-pixel application, our new method uses separate measurements of the IPC kernel to calculate the gain almost instantaneously. Using test data from a flight detector of the ESA Euclid mission, the IPC correction recovers the results of slower methods with 0.1% accuracy. The nonlinearity correction ensures that the estimated gain is independent of signal, correcting a bias of more than 2.5%.

Fields of Study & Subjects

CCD and CMOS Imaging Sensors Particle Detector Development and Performance Analog and Mixed-Signal Circuit Design

Publication details

Journal / source
Springer Link (Chiba Institute of Technology)
Publication date
16 January 2026
Language
EN