Clinical Outcomes after Implantation of the Toric Tecnis Eyhance Intraocular Lens: a Retrospective Analysis

View at publisher
Authors: Rafael Lucena, Christoph Tappeiner, Marco Langenegger, David Goldblum, Tamer Tandogan
Cited by: 0
References: 16

Abstract

Abstract: BACKGROUND: The Tecnis Eyhance Toric intraocular lens (IOL) model DIU00 (Johnson & Johnson) is a monofocal IOL with a slightly enhanced depth of focus, designed to improve intermediate vision while correcting corneal astigmatism in cataract surgery. While its optical concept has been validated in clinical trials, evidence from routine practice is still limited. The purpose of this study was to evaluate real-world visual and refractive outcomes, postoperative astigmatism, and patient satisfaction following implantation of the Eyhance Toric IOL. Abstract: METHODS: A total of 160 eyes from 97 consecutive patients were analysed, including 63 patients who underwent a bilateral procedure and 34 who had unilateral surgery with Eyhance Toric implantation. Preoperative biometry comprised axial length, anterior chamber depth, lens thickness, sulcus-to-sulcus distance, and keratometry values. At 1 month, monocular and binocular visual acuities (uncorrected [UDVA], corrected [CDVA], uncorrected intermediate [UIVA], distance-corrected intermediate [DCIVA], uncorrected near [UNVA], distance-corrected near [DCNVA]), manifest refraction, and keratometry were evaluated. Abstract: RESULTS: At 1 month, mean monocular UDVA, CDVA, UIVA, DCIVA, and UNVA were 0.12, 0.05, 0.06, 0.07, and 0.29 logMAR, respectively. Binocular UDVA, UIVA, and UNVA were 0.04, 0.03, and 0.24 logMAR, respectively. Mean corneal astigmatism decreased from - 1.70 ± 0.91 D to a postoperative refractive astigmatism of 0.31 ± 0.24 D (p < 0.0001). No IOL rotations were required. Spectacle independence was achieved in 13 patients (20.64%), while 50 (79.36%) required reading glasses. Among those targeted for bilateral emmetropia, 35 (87.5%) of 40 needed reading spectacles, compared with 15 (65%) of 23 patients with a mini-monovision refractive targe (p = 0.048). No disturbing dysphotopsias such as halos or glare were reported. Abstract: CONCLUSION: The Tecnis Eyhance Toric IOL demonstrated favourable outcomes for distance and intermediate vision, reliable astigmatism correction, and high patient satisfaction.

Fields of Study & Subjects

Intraocular Surgery and Lenses Ophthalmology and Visual Impairment Studies Total Knee Arthroplasty Outcomes

Publication details

Journal / source
Klinische Monatsblätter für Augenheilkunde
Volume
243
Issue
04
Pages
330–334
Publication date
11 February 2026
Language
DE