Contrast-Enhanced Ultrasound (CEUS) in Pregnancy: A Comprehensive Review of Clinical Applications

Read full text
Authors: Kaltra Begaj, Andreas Georg Sperr, Dirk‐André Clevert
Cited by: 2
References: 40

Abstract

Background: Imaging during pregnancy presents unique challenges. Computed tomography (CT) is generally avoided due to fetal radiation exposure, and magnetic resonance imaging (MRI) may be limited by concerns regarding gadolinium-based contrast agents. As a result, ultrasound (US) remains the primary imaging tool during pregnancy. Contrast-enhanced ultrasound (CEUS) expands the diagnostic capabilities of conventional US by providing real-time vascular information comparable to contrast-enhanced CT or MRI. Importantly, microbubble contrast agents used in CEUS do not cross the placenta and have shown no fetal harm in clinical studies. Nevertheless, CEUS remains an off-label technique during pregnancy, underscoring the need for a comprehensive review of the available literature to assess its safety and clinical applications during pregnancy. Method: This review summarizes the current evidence up to 2025 on the use of CEUS in pregnancy and highlights its clinical value with respect to evaluating acute and chronic maternal conditions - including oncologic, vascular, infectious, inflammatory, and other organ-specific pathologies - illustrated through representative case examples. Clinical studies, case reports, and international guidelines were analyzed with a focus on safety and diagnostic performance. Conclusion: Although still off-label, CEUS demonstrates an excellent safety profile and high diagnostic utility when clinically indicated in pregnancy. No maternal, fetal, or neonatal adverse effects have been reported, and no placental transfer of microbubbles has been demonstrated. CEUS enables high-resolution assessment of abdominal organs, vascular pathologies, and inflammatory or infectious changes, reducing the need for ionizing or gadolinium-based imaging. It represents a safe, effective, and radiation-free diagnostic alternative when conventional imaging is limited. Key Points: · CEUS expands diagnostic ultrasound without radiation exposure.. · CEUS is a safe alternative to CT or MRI.. · Microbubbles remain intravascular and do not cross the placenta.. · No maternal, fetal, or neonatal adverse effects reported.. · Case examples illustrate safety and diagnostic value.. Citation Format: · Begaj K, Sperr AG, Clevert DA. Contrast-Enhanced Ultrasound (CEUS) in Pregnancy: A Comprehensive Review of Clinical Applications. Rofo 2026; DOI 10.1055/a-2784-9759.

Fields of Study & Subjects

Ectopic Pregnancy Diagnosis and Management Ultrasound in Clinical Applications Ultrasound and Hyperthermia Applications

Publication details

Journal / source
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Publisher
Georg Thieme Verlag KG
Volume
198
Issue
09
Pages
1165–1173
Publication date
10 February 2026
Language
DE