Evaluation of the Feasibility and Safety of Left Ventricular Pacing Using Left Bundle Branch Area Pacing (LBBAP) Without Backup Right Ventricular Pacing Lead

View at publisher
Authors: M. Ali, Marc Irqsusi, D. Sequeda-Cubides, Maximilian Vondran, Ardawan Julian Rastan, Tamer Ghazy
Cited by: 0

Abstract

All articles of this category (opens in new window) Background: This study aims to evaluate the feasibility and safety of sole left ventricular pacing using left bundle branch area pacing (LBBAP) without a backup right ventricular lead. Methods: Patients who were over 18 years old and received a pacemaker with left bundle branch area pacing (LBBAP) with no additional right ventricular lead implantation from June 2023 through October 2024 in a single center were included. Patients with incomplete documentation and those who failed to provide informed consent were excluded. Preoperative, intraoperative, and postoperative data were retrospectively collected. A prospective follow-up with determination of changes in Rheobase, lead impedance, and sensing (postoperatively, at 6 weeks, and at 6 months) was documented, as well as lead dislocation or pacemaker-related complications. NT-pro-BNP values were evaluated 6 months after implantation. Results: A total of 42 patients were included, with a mean age of 77 ± 10 years, 68% males, 83% in sinus rhythm, mean EF of 54 ± 7%. The main indication was a third-degree AV-Block (34%), bradycardia-tachycardia syndrome (24%) sick sinus syndrome (24%). The mean operative time was 60 ± 10 minutes. The mean radiation dose was 1,103 ± 561 (cGy) cm 2 The LBBAP QRS time was 112 ms. Three patients suffered a postoperative hematoma and were treated conservatively. Two patients suffered a dislocation of the LBBA lead, and they were repositioned. During follow-up, one patient died of pneumonia. The follow-up data were complete for the remaining 41 patients. There were no late dislocations or pacemaker-related complications. The Rheobase significantly increased from a mean of 0.55 mV after implantation to 0.82 mV after 6 weeks ( p < 0.001) and did not change significantly after 6 months (0.82 vs. 0.69 mV, respectively, p > 0.999). The mean electrode impedance improved significantly after 6 weeks (391 vs. 469 Ohm perioperatively, p = 0.02) and did not change significantly after 6 months. The sensing did not change significantly over time (11.8 vs. 12.3 vs. 12.2 mV; p = 0.085). The NT-proBNP did not change significantly over 6 months (1,422 vs. 2,001 pg/mL ; p = 0.764). Conclusion: LBBAP is a safe and stable approach that provides a more physiological pacing. The pacing electrodes are stable, their parameters stay stable over time, and a dislocation is only seen perioperatively. A backup right ventricular lead may not be needed with increased experience, yet longer perioperative monitoring might be warranted to exclude perioperative dislocation. Publication History Article published online: 17 February 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Fields of Study & Subjects

Cardiac pacing and defibrillation studies Cardiac electrophysiology and arrhythmias Cardiac Arrhythmias and Treatments

Publication details

Journal / source
The Thoracic and Cardiovascular Surgeon
Volume
74
Issue
S 01
Pages
S1–S70
Publication date
1 January 2026
Language
EN