Release Criteria for Therapies with 177Lu-labeled Radiopharmaceuticals

View at publisher Summarise with VIRAT
Authors: E Rathsmann
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Ziel/Aim: In recent years, the number of patients treated with 177 Lu-labeled radiopharmaceuticals was on the increase. This trend is set to continue. However, the European Commission’s final report on the SAMIRA study criticises the lack of uniform release criteria. This work aims to investigate practical release criteria for 177 Lu-therapies and to compare them with each other. Methodik/Methods: Whole-body dose rates of 17 patients with mCRPC (mean age (70±6) years) treated with 177 Lu-PSMA-617 (Pluvicto TM , mean activity (7713±134) MBq) were measured at a distance of 1 m from the patient’s surface from the anterior and posterior view while standing at 9 time points p.i. The dose rate was calculated as the geometric mean. The data were fitted by a mono-exponential and a bi-exponential curve using R. The AIC was calculated for both models. The radiation dose to the public was calculated based on typical daily exposure situations for people who are most affected based on an equation derived from the bi-exponential model. Common release criteria were compared with each other in terms of radiation exposure. Ergebnisse/Results: The dependence of the coefficient of variation on the measurement time indicates that the measured dose rate is superior to a fixed discharge time as a release criterion. The calculated values of the AIC illustrate that the bi-exponential model is superior to the mono-exponential model in describing the decay behaviour of the dose rate. Therefore, the mono-exponential model underestimates the radiation exposure to the public. For the calculation of the radiation dose to the public, the use of individual half-lives after 48 h is sufficient. For a conservative estimation of the radiation dose to the public, the maximum number of cycles per year must be considered. Schlussfolgerungen/Conclusion: If a patient is discharged with a dose rate greater than 2.9 µSvh -1 , this leads to a significant radiation exposure in the event of patient non-compliance with contact restrictions.

Fields of Study & Subjects

Radiopharmaceutical Chemistry and Applications Radiation Dose and Imaging Radioactivity and Radon Measurements

Publication details

Journal / source
Nuklearmedizin - NuclearMedicine
Volume
65
Issue
02
Pages
142–142
Publication date
1 April 2026
Language
DE