How Low Can You Go: Quantitative Robustness of FAPI Breast PET at Ultra-Low Activity Levels and Flexible Scan Timing

View at publisher Summarise with VIRAT
Authors: P Brüggemann, David Ventura, P Dorten, Florian Büther, J Tio, Michael Andreas Schäfers, Matthias Christian Burg, Philipp Backhaus
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Ziel/Aim: The objective of this retrospective study was to determine the optimal administered activity and scan timepoint for dedicated breast FAPI PET/MRI. Methodik/Methods: Twenty-seven dedicated breast FAPI PET/MRI studies were included. Each protocol consisted of a 24-minute simultaneous single-bed acquisition. Simulated PET images at activity levels between 2 MBq/Kg and 0.125 MBq/Kg were reconstructed from raw list-mode data to emulate dose reduction. For 23 patients, three consecutive 8-minute subframes representing early, mid and late acquisition phases were additionally reconstructed. Tumor lesions, lymph nodes and reference regions were segmented using identical VOIs across all reconstructions to obtain quantitative parameters (SUV max , Tumor- and lymph node-to-background ratios TBR max , LBR max ). Histopathology and clinical follow-up served as reference standard for lesion classification. Receiver operating characteristic analysis with DeLong’s test was applied to compare diagnostic performance across doses and scan time points. Ergebnisse/Results: The mean administered activity was 137 MBq±54 MBq; in dynamic datasets the mean delay between tracer administration and image acquisition was 29 minutes±5 minutes. AUC values for full-dose versus lowest-dose images (0.125 MBq/Kg) showed no significant difference for breast lesions using SUVmax (AUC 0.93 vs. 0.92, p=0.62) or TBR max (AUC 0.96 vs. 0.96, p=0.94). For lymph nodes, the diagnostic performance also remained stable (SUVmax: AUC 0.92 vs. 0.95, p=0.13; LBR max : AUC 0.93 vs. 0.94, p=0.35). Across temporal subframes, no systematic trend or significant difference was observed (SUV max : AUC 0.94 vs. 0.93, p=0.57; LBR max : AUC 0.94 vs. 0.94, p=0.43). Schlussfolgerungen/Conclusion: Quantitative FAPI-PET measurements remained stable even at extremely low levels of administered activity and were largely independent of scan timing. The optimal administered activity may therefore depend mostly on reader preference for perceived image quality. These findings support FAPI-PET as a robust oncologic imaging tool and underline its potential for diagnostic work-up where radiation dose is a major constraint.

Fields of Study & Subjects

Medical Imaging Techniques and Applications Peptidase Inhibition and Analysis Radiopharmaceutical Chemistry and Applications

Publication details

Journal / source
Nuklearmedizin - NuclearMedicine
Volume
65
Issue
02
Pages
149–149
Publication date
1 April 2026
Language
DE