Diagnostic Performance of FAPI Breast PET/MRI: A Systematic Evaluation of Quantitative PET Parameters and Correlation with MRI

View at publisher Summarise with VIRAT
Authors: P Brüggemann, P Dorten, Florian Büther, J Tio, Michael Andreas Schäfers, Matthias Christian Burg, Philipp Backhaus
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Ziel/Aim: The objective of this retrospective study was to systematically compare quantitative parameters in FAPI breast PET/MRI to identify the metric with the highest diagnostic performance. In addition, several segmentation thresholds were evaluated to determine the parameter showing the best size correlation with MRI. Methodik/Methods: A total of 44 dedicated breast FAPI PET/MRI examinations performed for various clinical indications were included. Standardized volumes of interest (VOIs) were defined for tumor lesions, benign breast lesions, axillary lymph nodes, and reference regions. In addition to standard parameters (SUV max , SUV mean , SUV peak ), SUV mean variants generated using different segmentation thresholds as well as tumor- and lymph-node-to-background ratios (TBR, LBR) based on different reference regions were analyzed. Diagnostic performance of the different metrics was compared using ROC analysis with DeLong’s test. The maximum axial lesion diameter after threshold-based segmentation was correlated with MRI measurements. Ergebnisse/Results: FAPI PET/MRI of the breast demonstrated a strong diagnostic separation between malignant and benign breast lesions and lymph nodes. The best performing parameter was TBR max/max using the contralateral breast parenchyma as reference region (AUC 0.93 vs. SUV max 0.90, p=0.39). The difference from standard parameters was most pronounced in the subgroup of patients after neoadjuvant treatment (AUC 0.92 vs. SUV max 0.82, p=0.14). For lymph node differentiation, the best parameter was LBR max/mean with blood-pool as reference (AUC 0.95), though not significantly different from SUV max (AUC 0.94, p=0.34). The maximum axial lesion diameter on FAPI PET correlated significantly with MRI lesion size, with the best correlation achieved using a threshold of 1.8×SUV mean of normal breast parenchyma (r=0.79, p

Fields of Study & Subjects

Peptidase Inhibition and Analysis Medical Imaging Techniques and Applications MRI in cancer diagnosis

Publication details

Journal / source
Nuklearmedizin - NuclearMedicine
Volume
65
Issue
02
Pages
150–150
Publication date
1 April 2026
Language
DE