Abstract

Ziel/Aim: Evaluate the accuracy of automated segmentation tools (TotalSegmentator (TS) [ 1 ] for prostate and AutoPET3 [ 2 ] for tumour regions) by comparing their segmentations with human annotations using Dice-Sørensen coefficient (DSC) and 95th percentile Hausdorff distance (HD). Methodik/Methods: We retrospectively analysed in-house PSMA-PET/CTs from 372 prostate cancer (PCa) patients. Prostate and tumour regions were segmented using TS and AutoPET3, respectively. Manual segmentations of the prostate (including seminal vesicles) and primary tumour, performed by a nuclear medicine physician in training and reviewed by an expert, served as reference. Of the 372 patients, 335 were included in the prostate and 313 in the tumour analysis, with exclusions due to technical segmentation errors, CT artifacts, or lack of spatial overlap between AI-based tumour and prostate segmentations. Ergebnisse/Results: For prostate segmentation, the mean (95% CI) DSC and HD were 0.60 (0.59–0.61) and 25.19 mm (24.29–26.09 mm), respectively. For tumour segmentation, corresponding values were 0.60 (0.58–0.63) and 13.64 mm (11.93–15.34 mm). Tumour DSC are consistent with those reported in the original AutoPET3 study, which documented a mean DSC of 0.60 for PSMA-positive patients. TS prostate masks were systematically smaller than manual delineations with a mean relative difference of 52±12%, approximately one-third of which can be attributed to the inclusion of seminal vesicles in the manual segmentations. Schlussfolgerungen/Conclusion: AutoPET3 provided reasonably accurate automatic prostate tumour segmentations consistent with manual/expert delineations. The reduced precision may reflect some limitations, potentially due to factors such as partial-volume effects. TS fails to adequately segment enlarged prostates, likely due to its training on populations not representative of older men with prostate enlargement or PCa, restricting its use in routine urologic oncology.

Fields of Study & Subjects

Medical Image Segmentation Techniques Artificial Intelligence in Healthcare and Education Radiomics and Machine Learning in Medical Imaging

Publication details

Journal / source
Nuklearmedizin - NuclearMedicine
Volume
65
Issue
02
Pages
172–172
Publication date
1 April 2026
Language
DE