F-18-PSMA using a next generation 148 cm LAFOV PET/CT: Effect of scan duration on lesion signal and background noise

View at publisher Summarise with VIRAT
Authors: Desiree Weiberg, P Rath, S Kröhn, L R Nikoukar, A-M Uhlemann, Katarina Henning, S Ziegler, Frank Michael Bengel
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Ziel/Aim: Next generation long axial field of view (LAFOV) PET/CT scanners offer much higher molecular sensitivity and higher spatial resolution, enabling shorter acquisition time as compared to previous standard axial field of view (SAFOV) scanners. However, tracer-specific acquisition protocols are not yet standardized. We evaluated the effect of novel reconstruction techniques and shorter scan duration on static image quality of F-18-PSMA studies. Methodik/Methods: Using the Panorama GS 148cm LAFOV PET/CT (United Imaging Healthcare), we evaluated the data of 10 patients with prostate cancer, who underwent a 5 min list-mode F-18-JK-PSMA-7 scan (standard dose 3 MBq/kg bodyweight) 90min p.i. and low-dose CT for attenuation correction. List-mode data were re-sampled to 300, 150, 60, 30 and 15 sec static datasets. Each was reconstructed using standard OSEM iterative algorithm and a manufacturer-provided advanced iterative algorithm (hyper iterative, HI). Lesion signal strength was measured by SUVpeak and SUVmax in 3 lesions per patient, and change was defined relative to OSEM 300 sec as reference. Automated CT-based organ segmentation was employed and Coefficient of Variation (CoV) for SUVmean of the lesion-free liver was used as a measure of background noise. Ergebnisse/Results: Independent of scan duration, CoV remains stable from 27 to 30% for OSEM reconstruction and from 26 to 28% for HI reconstruction. Relative change of lesional SUVpeak ratio was low at 1 to 4% between all scan durations for both reconstruction methods. For SUVmax, shorter OSEM scan duration increases relative change up to 8%, while HI reconstruction shows higher lesional SUVmax ratios up to 13% for longer scan durations. Schlussfolgerungen/Conclusion: For F-18-PSMA imaging with standard injected activity, LAFOV PET enables a reduction of acquisition time down to 15 sec without increase of background noise or loss of lesion signal strength measured by SUVpeak. Alternatively, an imaging protocol with 25% lower injected activity and 1 min scan duration could be chosen. SUVmax is more susceptible to different scan durations and reconstruction algorithms and should thus be used with care for SUV-based image analysis.

Fields of Study & Subjects

Medical Imaging Techniques and Applications Radiation Dose and Imaging Radiopharmaceutical Chemistry and Applications

Publication details

Journal / source
Nuklearmedizin - NuclearMedicine
Volume
65
Issue
02
Pages
178–178
Publication date
1 April 2026