High-Flow or Standard Oxygen in Acute Hypoxemic Respiratory Failure

View at publisher
Authors: Jean-Pierre Frat, J. Quenot, Christophe Guitton, Rémi Coudroy, Arnaud Gacouin, Julio Badie, Alexandre Demoule, Damien Contou, Guillaume Carteaux, Stephan Ehrmann, Fabien Jarousseau, Nicholas Sédillot
+25 more J. Rigaud, Jean Reignier, François Beloncle, Anne‐Florence Dureau, Alexis Ferré, Cédric Daubin, Anna Bourreau, Agathe Delbove, G Pradel, Abdelhamid Fatah, Gwenhael Colin, Guillaume Deniel, Olivier Lamouret, Béatrice La Combe, Gwenael Prat, Louis-Marie Galerneau, Gaël Bourdin, Gautier Julien, Anaïs Curtiaud, Mélanie Saint-Léger, Emanuele Turbil, Faustine Reynaud, Louis Chamblet, Stéphanie Ragot, A. W. Thille
Cited by: 12
References: 29

Abstract

BACKGROUND: Data are needed on the effect of oxygen delivered through a high-flow nasal cannula, as compared with standard oxygen therapy, on intubation and mortality in patients with acute hypoxemic respiratory failure. METHODS: In this multicenter, open-label trial, we randomly assigned patients who had acute hypoxemic respiratory failure to receive high-flow-oxygen or standard-oxygen therapy. All the patients had a ratio of the partial pressure of arterial oxygen to the fraction of inspired oxygen of 200 or less, a respiratory rate of more than 25 breaths per minute, and pulmonary infiltrate on chest imaging. The primary outcome was death by day 28. RESULTS: A total of 1116 patients underwent randomization. Of these patients, 1110 (556 in the high-flow-oxygen group and 554 in the standard-oxygen group) were included in the analysis. Mortality at day 28 was 14.6% (in 81 of 556 patients) in the high-flow-oxygen group and 14.6% (in 81 of 554 patients) in the standard-oxygen group (difference, -0.05 percentage points; 95% confidence interval [CI], -4.21 to 4.10; P = 0.98). The incidence of intubation by day 28 was 42.4% (in 236 of 556 patients) in the high-flow-oxygen group and 48.4% (in 268 of 554 patients) in the standard-oxygen group (difference, -5.93 percentage points; 95% CI, -11.78 to -0.08). Serious adverse events (cardiac arrest or pneumothorax) occurred during spontaneous breathing in 13 patients (2.3%) in the high-flow-oxygen group and in 6 patients (1.1%) in the standard-oxygen group. CONCLUSIONS: Among patients with acute hypoxemic respiratory failure, the use of oxygen delivered through a high-flow nasal cannula did not significantly reduce mortality at day 28. (Funded by the French Ministry of Health and Fisher and Paykel Healthcare; SOHO ClinicalTrials.gov number, NCT04468126.).

Fields of Study & Subjects

Respiratory Support and Mechanisms Airway Management and Intubation Techniques Cardiac Arrest and Resuscitation

Publication details

Journal / source
New England Journal of Medicine
Publisher
Massachusetts Medical Society
Volume
394
Issue
21
Pages
2095–2106
Publication date
17 March 2026