Structural Failure of Pretensioned Concrete Sleepers under Cyclic Loading Due to Water Flow in Cracks

View at publisher
Authors: Josué César Bastos, Marcus S. Dersch, John Riley Edwards
Cited by: 0
References: 32

Abstract

Pretensioned concrete sleepers are vulnerable to structural failure when flexural cracks develop in moisture-rich environments. This study presents experimental evidence showing that water ingress in cracked regions leads to accelerated degradation under cyclic loading. Tests conducted on full-scale sleepers and small-scale prisms revealed that (1) debonding between tendons and concrete significantly increases compressive stresses, and (2) moisture reduces the concrete’s compressive strength. Notably, post-tensioned sleepers exhibited greater resistance to failure under similar conditions. Tendon corrosion, while a long-term concern, was not a contributing factor within the observed failure timeframe. These findings support recommendations for improved drainage and favoring unbonded post-tensioned systems in high-moisture settings.

Fields of Study & Subjects

Railway Engineering and Dynamics Structural Engineering and Materials Analysis Concrete Corrosion and Durability

Publication details

Journal / source
Journal of Transportation Engineering Part A Systems
Volume
152
Issue
4
Publication date
13 February 2026
Language
EN