Abstract

This article presents the results of nonlinear static calculation of finite element models of columns reinforced with both GFRP and traditional steel reinforcement. The aim of the numerical experiment was to confirm the effect of the transverse and longitudinal reinforcement saturation step on the strength and deformability of reinforced concrete elements. Numerical simulations have shown that strength of specimen is maximum when the spacing of transverse reinforcement is as small as it is permitted by codes. It has been proved that the spacing of transverse reinforcement plays a key role in bearing capacity of RC compressive elements and makes it possible to implement non-metallic GFRP reinforcement in columns.

Fields of Study & Subjects

Structural Behavior of Reinforced Concrete Structural Load-Bearing Analysis Masonry and Concrete Structural Analysis