Application of an Empirical Density Law via Python for Aqueous Plutonium Chloride Systems for MCNP6

Read full text
Authors: Riley Bulso, Christopher Perfetti, Jennifer Alwin, Tara Lynam
Cited by: 0
References: 18

Abstract

Criticality safety models for aqueous plutonium chloride systems often contain a significant bias due to assumptions in material compositions. These systems are currently modeled as a fictitious metal-water mixture because little is known about the true solution density. Furthermore, no predictive density tools or capabilities for modeling aqueous plutonium chloride systems are approved for use at Los Alamos National Laboratory. Recent density measurements of this ternary system (PuCl3-HCl-H2O) have allowed for the development of a more realistic density law, which is applied in this work via an empirical method based in Python. This tool, entitled PuCS (Plutonium Chloride Solution tool) may be used to determine solution density and composition based on the plutonium content, acid content, and temperature for MCNP6 inputs. PuCS has been found to predict density within 2% of experimental data. MCNP6 calculations have found that crediting minimal amounts of free acid (0.5 M) may correspond to a ~12% decrease in peak reactivity in comparison to current modeling methods.

Fields of Study & Subjects

Nuclear reactor physics and engineering Nuclear Materials and Properties Radioactive element chemistry and processing

Publication details

Journal / source
Nuclear Technology
Publisher
Informa UK Limited
Pages
1–9
Publication date
3 February 2026
Language