Monte Carlo Simulation of a Neutron Detector for Orientation Measurement of Isotope Neutron Source

View at publisher
Authors: Lichao Tian, Zijia Zhao, G.B. Zhang
Cited by: 0
References: 19

Abstract

The orientation measurement of isotope neutron sources is critical in nuclear security and safeguards, particularly for monitoring special nuclear materials. This paper introduces a cubic neutron detection device composed of six planar neutron detectors for orientation detection in neutron source localization. A comprehensive Monte Carlo simulation was conducted, and the results showed that the planar neutron detector, based on CdTe/CdS semiconductor layers and 6Li foils, achieved a thermal neutron detection efficiency of approximately 50%. The orientation of the neutron source can be inferred from the relative neutron count ratios among the six planar detectors.To improve the measurement precision, machine learning algorithms, including k-nearest neighbor, random forest algorithm, and multi-layer perceptron were implemented using simulated data from a 252Cf neutron source at varying distances and orientations. The system achieved an angular classification accuracy exceeding 90% at 5-deg intervals, with regression-based models yielding a root-mean-square error of approximately 1 deg, confirming the effectiveness of the proposed approach for neutron source orientation detection.

Fields of Study & Subjects

Radiation Detection and Scintillator Technologies Nuclear Physics and Applications Advanced Semiconductor Detectors and Materials

Publication details

Journal / source
Nuclear Technology
Pages
1–9
Publication date
30 January 2026
Language
EN