The effect of dexmedetomidine in mechanically ventilated patients with sepsis and septic shock: a meta-analysis of randomized controlled trials

Read full text Summarise with VIRAT
Authors: Lin Chen, Weibing Wu, Yunxiang Chen, Minfeng Tong, Binbin Ren, Kai Zhang
Cited by: 0
References: 57

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Purpose Dexmedetomidine (DEX) is a central sympatholytic with sedative properties widely used in critically ill patients. However, its effects in patients with sepsis and septic shock remain controversial. This meta-analysis evaluated the efficacy and safety of DEX compared to other sedatives in mechanically ventilated patients with sepsis and septic shock.Methods A systematic search was conducted across PubMed, Embase, Scopus, and Cochrane Library from inception through May 1, 2025 for randomized controlled trials comparing DEX with other sedatives or placebo in mechanically ventilated patients with sepsis and septic shock. Primary outcomes included overall mortality and Sequential Organ Failure Assessment (SOFA) scores. Secondary outcomes encompassed duration of mechanical ventilation (MV), length of stay in Intensive Care Unit (ICU), incidence of hypotension and bradycardia.Results Fifteen studies involving 3,882 patients (1,945 in the DEX group, 1,937 in the control group) were included. DEX was demonstrated no significant differences compared to other sedatives or placebo in overall mortality (Risk Ratio [RR] 0.98, 95% Confidence Interval [CI] 0.90 to 1.07, p = 0.71, I2 = 0%), SOFA scores (Mean Difference [MD] − 0.14, 95% CI −0.81 to 0.52, p = 0.67, I2 = 0%), length of stay in ICU (MD −0.32, 95% CI −1.69 to 1.06, p = 0.65, I2 = 77%), or incidence of hypotension (RR 1.15, 95% CI 0.81 to 1.62, p = 0.44, I2 = 14%). However, DEX significantly reduced the duration of MV (MD −0.54, 95% CI −0.98 to −0.10, p = 0.02, I2 = 25%) but was associated with an increased incidence of bradycardia (RR 1.67, 95% CI 1.22 to 2.28, p = 0.001, I2 = 0%).Conclusions In mechanically ventilated patients with sepsis and septic shock, DEX shortened duration of MV but was associated increased bradycardia risk. No mortality or organ dysfunction benefits were observed. These findings suggest DEX is a reasonable therapeutic option to facilitate earlier ventilator weaning in selected patients (particularly those without shock), but careful monitoring for cardiovascular adverse effects is warranted.

Fields of Study & Subjects

Anesthesia and Sedative Agents Intensive Care Unit Cognitive Disorders Sepsis Diagnosis and Treatment

Publication details

Journal / source
Annals of Medicine
Volume
58
Issue
1
Pages
2643971–2643971
Publication date
17 March 2026
Language
EN