Comparative Evaluation of Intraocular Lens Power Calculation Formulas in Patients After Radial Keratotomy

Read full text
Authors: Enjie Li, Zhenyu Wang, Yangfan Yu, Xijin Wu, Yuxuan Jia, Peilin Yue, Ting Chen, Qi Zhang, Xudong Song
Cited by: 1
References: 31

Abstract

Objective This study assessing the performance of five intraocular lens (IOL) calculation methodologies in cataract patients with previous radial keratotomy (RK) history.Methods Five formulas predicted refractive outcomes, with prediction errors (PE) calculated by comparing formula-derived spherical equivalents to manifest refraction. Additional statistical analysis examined correlations between formula-specific PE and biometric parameters including axial length (AL) and corneal curvature.Results Overall, Barrett True-K and Hoffer QST showed minimal prediction bias (PE: −0.06D and −0.07D; p > 0.05). PEARL-DGS had the best stability (SD: 0.97) and led in ±0.25D accuracy (20.8%, p = 0.665). In AL subgroups, Barrett True-K showed superior accuracy for medium-long eyes (26.0–30.0 mm; PE closest to zero), while EVO 2.0 yielded significant hyperopic error in short AL eyes (

Fields of Study & Subjects

Ophthalmology and Visual Impairment Studies Corneal surgery and disorders Ocular Surface and Contact Lens

Publication details

Journal / source
Journal of Investigative Surgery
Publisher
Informa UK Limited
Volume
39
Issue
1
Pages
2622155–2622155
Publication date
17 February 2026
Language