Lung ultrasound features during the evolution of BPD: a study from an animal model

Read full text
Authors: Haifeng Zong, Cuihui Li, Nan Ye, Jingyu Song, Lingling Yang, Su Fang, Jipeng Shi, Xueyu Chen, Chuanzhong Yang
Cited by: 1
References: 20

Abstract

OBJECTIVE: To explore lung ultrasound (LUS) in the evolution of bronchopulmonary dysplasia (BPD) and the diagnostic value of LUS in BPD. METHODS: ) group. LUS were performed at 12 h and on the 3rd, 7th, and 10th days to explore the LUS in BPD rats. Hematoxylin-eosin staining and immunohistochemical were analyzed to evaluate pathological characteristics. RESULTS: group was significantly increased on the 7th and 10th days. In the early stage, LUS revealed multiple B-lines and air bronchograms. In the late stage, LUS revealed anechoic echoic areas on the pleural surface and scattered dot-like hyperechoic patterns in the lung field. The LUS findings were consistent with the pathological results. CONCLUSION: There was a strong positive correlation between LUS and pathological findings. LUS can be used to monitor the evolution of BPD.

Fields of Study & Subjects

Ultrasound in Clinical Applications Ultrasound and Hyperthermia Applications Ultrasound Imaging and Elastography

Publication details

Journal / source
The Journal of Maternal-Fetal & Neonatal Medicine
Publisher
Informa UK Limited
Volume
39
Issue
1
Pages
2611637–2611637
Publication date
8 January 2026
Language
EN