Experimental measurements of biofilm thickness in drinking water pipes

Read full text
Authors: Konstantinos Glynis, Mirjam Blokker, Zoran S. Kapelan, Dragan A. Savic
Cited by: 1
References: 48

Abstract

Biofilms in drinking water distribution systems (DWDS) challenge water quality, infrastructure and public health. Current monitoring methods often disrupt biofilms or lack spatial coverage. This study explores two novel, non-intrusive techniques to measure biofilm thickness: one based on heat resistance, the other on changes in hydraulic residence time. Experiments were conducted in a lab-scale DWDS simulator replicating realistic pipe conditions. Both methods were evaluated against traditional destructive sampling to assess accuracy. Results show that the residence time method yields consistent, reliable estimates closely matching physical samples, while the heat resistance approach shows greater variability and requires refinement. Sensitivity analyses further demonstrate that the residence time method is more robust under varying operational conditions. These findings highlight its potential for field deployment, offering a scalable and minimally invasive solution for real-time biofilm monitoring. This advancement could support improved water quality management through targeted interventions in actual DWDS environments.

Fields of Study & Subjects

Water Treatment and Disinfection Fecal contamination and water quality Bacterial biofilms and quorum sensing

Publication details

Journal / source
Urban Water Journal
Publisher
Informa UK Limited
Volume
23
Issue
7
Pages
1087–1104
Publication date
16 February 2026
Language