Multi-scale optimal control for Einstein Telescope active seismic isolation
Abstract
Abstract We present a multi-scale optimal control framework for active seismic isolation in the Einstein Telescope (ET), a third-generation gravitational-wave observatory. Our approach jointly optimizes feedback and blending filters in a cross-coupled opto-mechanical system using a unified cost function based on an ‘acausal optimum’, that quantifies the sensor signal-to-noise ratios and disturbances versus frequency. This method enables efficient re-optimization under varying sensor configurations and environmental conditions. We apply the framework to two candidate sensing systems using their modeled sensitivity: OmniSens-a six-degree-of-freedom inertial isolation system-and BRS-T360, which combines beam rotation sensor (BRS) as an inertial tilt sensor with T360 as a horizontal seismometer. We demonstrate superior low-frequency isolation with OmniSens, reducing platform motion by up to two orders of magnitude near the microseism. The framework allows for ready optimization and projection of sensor noise to metrics relevant to the performance of the instrument, aiding the design of the ET.
Fields of Study & Subjects
Pulsars and Gravitational Waves Research
Geophysics and Sensor Technology
Geophysics and Gravity Measurements
Publication details
- Journal / source
- Classical and Quantum Gravity
- Publisher
- IOP Publishing
- Volume
- 43
- Issue
- 2
- Pages
- 025004–025004
- Publication date
- 6 January 2026