Adaptive geometric-attention multi-task framework with knowledge distillation for aortic dissection detection in non-contrast CT

View at publisher
Authors: Rongli Zhang, Zhiquan Situ, Zhangbo Cheng, Yande Luo, Xiongfeng Qiu, Xin He, Xinchen Yuan, Zijie Zhou, Zhaowei Rong, Yunhai Lin, Qi Li, Bin Sun
+4 more H. B. Wu, Huilin Jiang, Wu Zhou, Guoxi Xie
Cited by: 1
References: 59

Abstract

Abstract Aortic dissection (AD) is a life-threatening cardiovascular emergency. Non-contrast-enhanced computed tomography (NCE-CT) could provide timely AD screening with fewer contraindications compared to CE-CT imaging. However, NCE-CT examinations lack distinctive imaging characteristics of AD, leading to high rates of missed diagnoses and misdiagnoses, and increased radiologist workload. In this paper, we propose a novel end-to-end multi-task framework for automated aortic segmentation and AD detection using NCE-CT images. The framework comprises three main components: a deformable feature extractor enhancing aorta tubular-feature attention, an adaptive geometric information extraction module to optimize feature sharing between segmentation and classification tasks via the transformer cross-attention mechanism, and a knowledge distillation module transferring diagnostic information from the CE-CT-based teacher model to the NCE-CT-based student model. Multi-center tests across 3 internal and 2 external centers demonstrated that our model outperformed existing methods both for segmenting the aorta and detecting AD. Specifically, for segmenting the aorta, our framework achieved dice of 0.928 and 0.909, Jaccard index (JI) of 0.867 and 0.858, mean intersection over union (MIoU) of 0.932 and 0.913, and frequency-weighted IoU (FWIoU) of 0.995 and 0.994, in internal and external testing datasets, respectively. For identifying AD patients from non-AD patients, our framework achieved accuracies of 0.911 and 0.840, sensitivities of 0.925 and 0.888, and F 1-scores of 0.922 and 0.836, in internal and external testing datasets, respectively. Ablation experiment demonstrates the effectiveness of each module. The proposed model may serve as an effective diagnostic assistant for radiologists, acting as a ‘second pair of eyes’ to assist in AD screening using NCE-CT images.

Fields of Study & Subjects

Medical Image Segmentation Techniques Medical Imaging and Analysis Aortic Disease and Treatment Approaches

Publication details

Journal / source
Physics in Medicine and Biology
Publisher
IOP Publishing
Volume
71
Issue
3
Pages
035011–035011
Publication date
20 January 2026
Language
EN