Motion-robust magnetic resonance fingerprinting (MR-MRF) for quantitative liver cancer imaging

Read full text
Authors: Chenyang Liu, Tian Li, Lu Wang, Yat-Lam Wong, Mandi Wang, Huiqin ZHANG, Zuojun Wang, Haonan Xiao, Shaohua Zhi, Wen Li, Jiang Zhang, Xinzhi Teng
+3 more Victor Lee, Peng Cao, Jing Cai
Cited by: 1
References: 28

Abstract

Abstract Objective. This study aims to develop a motion-robust magnetic resonance fingerprinting (MR-MRF) technique for liver cancer imaging to eliminate the need for breath-hold scanning. Approach. To mitigate respiratory motion artifacts in free-breathing abdominal MRF, the MR-MRF technique comprising two core components. First, respiratory motion is modeled by applying an isotropic total variation (TV)-regularized registration algorithm between a target end-of-exhalation (EOE) phase and three motion phases. Second, motion-resolved tissue property maps are reconstructed using a low-rank TV optimization framework, which incorporates the estimated inter-phase motion to align all acquired MRF dynamics to the EOE phase. MR-MRF is evaluated by 22 patients (mean age, 62 years ± 10 [SD]; 15 males and 7 females) with hepatocellular carcinoma. Radiologist’s blinded assessment and organ boundary sharpness measurements are performed to evaluate the image quality of MR-MRF-derived tissue maps. The test-retest tissue quantification repeatability is assessed by two consecutive MRF scans with distinct breathing patterns. Paired Student’s t -test is used for statistical significance analysis with a p -value threshold of 0.05. Main results. MR-MRF achieved successful reconstruction of motion-resolved tissue maps at EOE phase, with blinded radiologist assessment yielding an average score of 3 (moderate quality—sufficient for diagnosis) for overall image impression. The FWHM of organ boundaries in MR-MRF-derived tissue maps is 3.1 mm ± 1.7 mm, significantly lower than motion-blurred tissue maps (9.9 mm ± 3.4 mm, p -value < 0.0001). Test-retest analysis demonstrated good repeatability: liver coefficient of variation was 5.5% ± 7.1% (T1), 8.2% ± 4.4% (T2), and 5.0% ± 2.0% (PD), with excellent linear agreement ( R 2 = 0.96, 0.80, and 0.85 for T1, T2, and PD, respectively). Significance. This study establishes the technical foundation of MR-MRF to achieve repeatable and quantitative liver T1/T2/PD mapping under free-breathing conditions at 3 T. The results validate the feasibility of addressing respiratory motion in abdominal multi-parametric quantitative MRI.

Fields of Study & Subjects

MRI in cancer diagnosis Hepatocellular Carcinoma Treatment and Prognosis Advanced MRI Techniques and Applications

Publication details

Journal / source
Physics in Medicine and Biology
Publisher
IOP Publishing
Volume
71
Issue
3
Pages
035015–035015
Publication date
20 January 2026
Language
EN