Investigating the timing behavior of compton scattering in BGO for time-of-flight PET
Abstract
Abstract Objective . Bismuth germanate (BGO) has regained attention as a promising material for hybrid Cherenkov/scintillation time-of-flight positron emission tomography (TOF-PET). While excellent timing performance has been demonstrated in single-crystal studies using prompt Cherenkov photons, practical pixelated detector modules introduce appreciable inter-crystal scattering ( InterCS ) events that can degrade timing accuracy. The objective of this work was to experimentally investigate the impact of InterCS on Cherenkov-based timing in pixelated BGO detectors and to identify optimal timestamp selection strategies. Approach . A dual-pixel BGO detector was constructed and coupled to a segmented SiPM readout to enable spatially resolved energy and timing measurements. Events were classified into full-energy deposition ( FED ); primary crystal 511 keV absorption), InterCS , and penetration categories using energy-weighted positioning. This experimental classification was validated using GATE simulations, which further revealed that intra-crystal scattering ( IntraCS ) accounted for more than 25% of the events experimentally classified as FED . Multiple timestamp selection strategies were evaluated, and prompt photon statistics were quantified by integrating the first 1 ns of the timing waveform. Main results . For InterCS events, selecting the earlier of the two timestamps yielded a coincidence timing resolution of 221 ps FWHM (831 ps FWTM) measured in coincidence with a LYSO:(Ce, Mg) reference detector, compared to 184 ps FWHM (603 ps FWTM) for FED events. Energy-based timestamp selection was found to be suboptimal. Prompt photon analysis showed a measurable reduction in early photon yield for InterCS events, with an average of 4.73 detected photons in the first 1 ns, compared to 5.76 for FED events. Significance . these results demonstrate that InterCS introduces systematic timing degradation in pixelated BGO Cherenkov TOF-PET detectors through energy redistribution and reduced prompt photon statistics. The findings highlight the necessity of time-aware, per-pixel timestamp selection strategies to preserve optimal timing performance in realistic BGO-based TOF-PET systems operating in the presence of Compton scattering.
Fields of Study & Subjects
Radiation Detection and Scintillator Technologies
Particle Detector Development and Performance
Medical Imaging Techniques and Applications
Publication details
- Journal / source
- Physics in Medicine and Biology
- Volume
- 71
- Issue
- 3
- Pages
- 035026–035026
- Publication date
- 28 January 2026
- Language
- EN