A metre-scale plasma discharge for plasma wakefield acceleration

Read full text
Authors: Nelson Lopes, Claudia Camila Cobo, Jian Bin Ben Chen, Paul-Bogdan Jurj, Lewis Kennedy, Alex Vanstone, Z. Najmudin
Cited by: 1
References: 21

Abstract

Abstract The construction, diagnosis, and analysis of a 1 m discharge argon plasma cell is presented for the application to plasma wakefield accelerator experiments. The specifications of the plasma cell were tailored towards the requirements of the advanced wakefield experiment at CERN. A high voltage (9 kV) switch was designed that produced square current pulses with 350 A peak current, variable pulse length between 5 µ s and 30 µ s and ( 54 ± 19 ) ns jitter. The switch was used to produce discharges for gas pressures in the 0.02–1 mbar range. The plasma was diagnosed using interferometry and spectroscopy. An argon plasma with equilibrium temperature of 0.75 eV for pulses longer than 10 µ s was produced when balancing the injection and evacuation of argon through the cell. Hydrogen contamination was identified when closing the gas injection and evacuation valves. This suppressed argon ionisation and produced plasmas with 28% total ionisation at 0.1 mbar measured using Stark broadening. 19% argon ionisation at 0.1 mbar was measured via interferometry in the absence of hydrogen contamination.

Fields of Study & Subjects

Electromagnetic Launch and Propulsion Technology Laser-Plasma Interactions and Diagnostics Pulsed Power Technology Applications

Publication details

Journal / source
Plasma Physics and Controlled Fusion
Publisher
IOP Publishing
Volume
68
Issue
4
Pages
045046–045046
Publication date
1 April 2026