Compensation of 1/1 and 2/2 error field in Wendelstein 7-X via divertor heat load symmetrization

Read full text
Authors: Yu Gao, S. Bozhenkov, Yuhe Feng, Sebastian Thiede, Marcin Jakubowski, J. Geiger, T. Stange, O. Grulke, Michael Endler, M. Otte, D. Naujoks, Joris Fellinger
+2 more Fabio Pisano, the EUROfusion Tokamak Exploitation Team
Cited by: 1
References: 24

Abstract

Abstract Recent experiments with the water-cooled, high-heat-flux divertor of the Wendelstein 7-X (W7-X) stellarator demonstrate substantial progress in error-field compensation. Numerical simulations reveal a pronounced sensitivity of divertor heat load distributions to error fields. Experimentally, wide-angle infrared cameras monitoring all ten divertor units show significant improvements in the symmetry of divertor thermal footprints when trim coils and control coils are employed to compensate intrinsic 1/1 and 2/2 error fields, respectively. The experimentally determined amplitude of the intrinsic 1/1 error field is consistent with results obtained seven years ago, despite different diagnostics, divertor components, and slight variation in magnetic configurations. For the first time, the intrinsic 2/2 error field has been compensated through a phase-scan experiment using control coil currents, supported and validated by simulations.

Fields of Study & Subjects

Magnetic confinement fusion research Fusion materials and technologies Superconducting Materials and Applications

Publication details

Journal / source
Nuclear Fusion
Publisher
IOP Publishing
Volume
66
Issue
7
Pages
076015–076015
Publication date
27 May 2026
Language
EN