Large-scale tests for the characterisation of the lpGBT stuck at power-up issue

Read full text
Authors: Daniel Hernandez Montesinos, S. Baron, Stefan Biereigel, S. Detraz, S. Kulis, Christophe Sigaud, Pedro Leitao, K. Wyllie
Cited by: 0
References: 3

Abstract

Abstract The Low-power Gigabit Transceiver (lpGBT) is a radiation-tolerant ASIC used in high-energy physics experiments for multipurpose high-speed bidirectional serial links. In 2024, almost 270,000 lpGBTs v1 were tested with a production test system that exercises the entire ASIC functionality to ensure its correct operation. Furthermore, qualification tests (Total Ionizing Dose, Single-Event Upsets, etc.) were done on lpGBTs from each production lot. Despite the thorough production and qualification tests, a design issue named “stuck at power-up” was discovered, affecting a maximum of 0.9% of delivered devices simultaneously. The test system setup developed for the characterisation of this behaviour and the results obtained are presented here.

Fields of Study & Subjects

Particle Detector Development and Performance Radiation Effects in Electronics VLSI and Analog Circuit Testing

Publication details

Journal / source
Journal of Instrumentation
Volume
21
Issue
01
Pages
C01015–C01015
Publication date
1 January 2026
Language
EN