Performance of the front-end electronics of the CMS electromagnetic calorimeter barrel for the High-Luminosity LHC

Read full text
Authors: Gilvan Alves, P. Rebello Teles, M.G. Ferreira Siqueira Amaral Gomes, T. Cao, M. Chen, S. Song, J. Tao, C. Wang, J. Wang, J. Zhang, N. Godinovic, D. Lelas
+88 more M. Kovac, A. Petkovic, P. A. Razis, K Aivazelis, F. Couderc, M. Dejardin, J.L. Faure, F. Ferri, S. Ganjour, P. Gras, F. Guilloux, G. Hamel de Monchenault, J. Malcles, F. Orlandi, S. Ronchi, P. Simkina, Z. Sun, M. Tornago, S. Vetter, G. Boldrini, T.D. Cuisset, T. Debnath, I.T. Ehle, L. Kalipoliti, M. Manoni, A. Zabi, A. Zghiche, P. Depasse, H. El Mamouni, J. Fay, S. Gascon, B. Ille, M. Lethuillier, R.M. Chatterjee, Sh. Jain, G. Majumder, S. Parolia, R. Saxena, S. Banfi, F. Cetorelli, A. Ghezzi, P. Govoni, G. Lavizzari, A. Massironi, G. Pizzati, S. Ragazzi, M.G. Strianese, M. Cipriani, C. Basile, R. Bianco, F. Cavallari, L. Cunqueiro Mendez, F. De Riggi, Marco Del Vecchio, E. Di Marco, M. Diemoz, L. Frosina, R. Gargiulo, A. Girardi, E. Longo, R. Lunadei, L. Martikainen, Jelena Mijuskovic, C. A. Nicolau, Giovanni Organtini, N. Palmeri, Francesco Pandolfi, R. Paramatti, F. Pellegrino, A. Pelosi, V. Pettinacci, C. Quaranta, S. Rahatlou, C. Rovelli, A. Villani, S. Argirò, N. Bartosik, C. Biino, C. Borca, F. Cossio, G. Cotto, D. Cristoforetti, G. Dellacasa, L. Finco, G. Mazza, P. Meridiani, Marco Monteno, Maria Margherita Obertino
Cited by: 0
References: 21

Abstract

Abstract The performance of the CMS electromagnetic calorimeter upgraded readout electronics, developed for the High-Luminosity phase of the LHC, is discussed. Data collected in two beam test campaigns conducted in 2018 and 2021 at the H4 and H2 beam lines of the CERN SPS are analyzed. Time and energy resolutions are measured on a 5× 5 matrix of lead tungstate crystals equipped with prototypes of the new front end readout electronics, using electron and pion beams of energies spanning from 25 to 250 GeV. In both campaigns the constant term of the energy resolution is measured to be better than 0.6% and the time resolution for electrons with energies above 50 GeV is measured to be better than 30 ps, fulfilling the design requirements.

Fields of Study & Subjects

Particle Detector Development and Performance Radiation Detection and Scintillator Technologies Particle Accelerators and Free-Electron Lasers

Publication details

Journal / source
Journal of Instrumentation
Volume
21
Issue
01
Pages
P01001–P01001
Publication date
1 January 2026
Language