Performance of USTC first batch resistive AC-LGAD sensor
Abstract
Abstract In this paper, the design and characterization of AC-LGAD sensors at the University of Science and Technology of China is introduced. The sensors are characterized with an infrared laser Transient Current Technique (TCT) system for evaluating signal response characteristics and spatial resolution. The temporal resolution was quantified with electrons emitted by a Sr-90 radioactive source. The spatial resolution can reach 4 μm and a temporal resolution of 48 ps is achieved.
Fields of Study & Subjects
Particle Detector Development and Performance
Radiation Detection and Scintillator Technologies
Advanced Semiconductor Detectors and Materials
Publication details
- Journal / source
- Journal of Instrumentation
- Publisher
- IOP Publishing
- Volume
- 21
- Issue
- 01
- Pages
- P01005–P01005
- Publication date
- 1 January 2026