Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

Read full text
Authors: A. Armatol, Alexander S. Barabash, David Baudin, V. Berest, M. Beretta, L. Bergé, M Buchynska, J. M. Calvo-Mozota, C. Capelli, P. Carniti, Maurice P. Chapellier, Ioan Dafinei
+35 more Fedor A. Danevich, Terry Dixon, Alexey Drobizhev, L. Dumoulin, F. Ferri, A. Gallas, Andrea Giuliani, C. Gotti, P. Gras, Aldo Ianni, L. Imbert, Hawraa Khalife, Vladislav Kobychev, Sergey I. Konovalov, Pia Loaiza, P.de Marcillac, S. Marnieros, Claire Akiko Marrache-Kikuchi, María Luz Peñas Martínez, Edoardo Mazzucato, C. Nones, E. Olivieri, A. Órtiz de Solórzano, M Pageot, Y. Peinaud, Víctor Pérez, G. Pessina, Denys V. Poda, P. Rosier, J. A. Scarpaci, B. Schmidt, V.I. Tretyak, V. I. Umatov, M.M Zarytskyy, A. Zolotarova
Cited by: 0
References: 54

Abstract

Abstract As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O (10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

Fields of Study & Subjects

Dark Matter and Cosmic Phenomena Particle physics theoretical and experimental studies Neutrino Physics Research

Publication details

Journal / source
Journal of Instrumentation
Publisher
IOP Publishing
Volume
21
Issue
01
Pages
P01035–P01035
Publication date
1 January 2026
Language
EN