Measurements of enriched 155 Gd and 157 Gd converters with the NMX detector on the n_TOF EAR2 beam line at CERN

Read full text
Authors: D. Pfeiffer, F.M. Brunbauer, I.R. Fehse, A.D. Finke, K. Fissum, K.J. Floethner, D. Janssens, M. Lisowska, H. Muller, E. Oksanen, E. Oliveri, L. Ropelewski
+6 more A. Rusu, J. Samarati, L. Scharenberg, M. van Stenis, R. Veenhof, N. Zavaritskaya
Cited by: 1
References: 17

Abstract

Abstract The detectors for the NMX instrument at the European Spallation Source (ESS) in Lund use natural Gd as the neutron converter. In 2024, beam time was obtained at the neutron time-of-flight experiment (n_TOF) at CERN to study the feasibility of an upgrade to enriched Gd. A 10 × 10 cm 2 prototype of the NMX detector was equipped with two enriched Gd samples ( 157 Gd and 155 Gd) that were attached with copper tape to the natural Gd cathode of the detector. Three sets of measurements were taken, with the beam focused on either the natural Gd, the 157 Gd, or the 155 Gd samples. Using the time-of-flight technique with the subsequent conversion of time-of-flight into energy, the resonant region between 1 eV and 200 eV of the 157 Gd and 155 Gd cross sections was studied. The peaks in the resonant region were clearly visible, having higher ADC values in the ADC spectrum. Additionally, the resonant peaks had a larger number of counts per energy bin. In the thermal neutron energy range, the count rate at the center of the beam was measured for natural Gd, 157 Gd, and 155 Gd. Enriched 157 Gd showed an efficiency that was between 60–180 % higher, compared to natural Gd, for neutron wavelengths between 0.8 Å and 1.8 Å. The measured 60 % increase in efficiency at 1.8 Å is lower than expected from mathematical modelling (100 %) and previous measurements with solid state detectors (80 %). Detection of capture gammas and gamma background, bad focusing and saturation effects most likely explain this deviation. An upgrade of the natural Gd converter to enriched 157 Gd would thus lead to an efficiency increase of at least 60 %. The measurements presented in this paper are the first successful time-of-flight measurements with the NMX detector prototype and the ESS VMM readout.

Fields of Study & Subjects

Radiation Therapy and Dosimetry Nuclear reactor physics and engineering Particle Accelerators and Free-Electron Lasers

Publication details

Journal / source
Journal of Instrumentation
Publisher
IOP Publishing
Volume
21
Issue
02
Pages
P02011–P02011
Publication date
1 February 2026
Language