Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

Read full text
Authors: Fatima Abd Alrahman, P. Abratenko, N. Abrego-Martinez, A. Aduszkiewicz, F. Akbar, L. Aliaga Soplin, Maria Artero Pons, J. Asaadi, W. Badgett, B. Behera, Vincenzo Bellini, R. Benocci
+88 more N. Berger, S. Berkman, O. Beltramello, S. Bertolucci, M. Betancourt, Adrien Blanchet, F. Boffelli, M. Bonesini, T. Boone, Bianca Bottino, Alberto Braggiotti, J. Bremer, S. J. Brice, V. Brio, C. Brizzolari, H. S. Budd, A. Campani, A. Campos, D. Carber, M. Carneiro, I. Caro Terrazas, H. Carranza, Francisco Fernandez, A. Castro, S. Centro, G. Cerati, M. Chalifour, P. Chambouvet, A. Chatterjee, D. Cherdack, S. Cherubini, N. Chithirasreemadam, T. E. Coan, A. Cocco, M. R. Convery, L. Cooper-Troendle, S. Copello, Hélio da Motta, M. Dall’Olio, A. A. Dange, ALBERT DE ROECK, S. Di Domizio, L. Di Noto, D. Di Ferdinando, M. V. Diwan, S. Dolan, L. Domine, S. Donati, Roza Doubnik, F. Drielsma, J. Dyer, S. Dytman, C. Fabre, Andrea Falcone, C. Farnese, A. Fava, N. Gallice, F. G. Garcia, C. Gatto, M. Geynisman, D. Gibin, A. Gioiosa, Weifeng Gu, A. Guglielmi, GS Gurung, K. Hassinin, H. Hausner, A. Heggestuen, B. Howard, Ryan T. Howell, Z. Hulcher, I. Ingratta, C. James, W. Jang, Y. -J. Jwa, L. Kashur, W. Ketchum, Kim Js, Dae Koh, J. Larkin, Yufeng Li, C. Mariani, Chris M. Marshall, Sergey I. Martynenko, N. Mauri, Kevin S. McFarland, D. P. Méndez, A. Menegolli
Cited by: 0
References: 35

Abstract

Abstract This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Fields of Study & Subjects

Particle Detector Development and Performance Particle physics theoretical and experimental studies Superconducting Materials and Applications

Publication details

Journal / source
Journal of Instrumentation
Publisher
IOP Publishing
Volume
21
Issue
04
Pages
P04012–P04012
Publication date
1 April 2026
Language
EN