Compact sub-10 ps resolution radio frequency photomultiplier tube

Read full text
Authors: S. Abrahamyan, S. Zhamkochyan, H. Rostomyan, A. Margaryan, H. Elbakyan, A. Kakoyan, A. Papyan, A. Safaryan, J. Annand, K. Livingston, R A Montgomery, S.N. Nakamura
+7 more P. Achenbach, J. Pochodzalla, D. L. Balabanski, V. Sharyy, D. Yvon, A. P. Aprahamian, V. Kakoyan
Cited by: 1
References: 8

Abstract

Abstract Experimental measurements of the radial spreading of photoelectrons emitted from a multi-alkali photocathode in a MCP-based photomultiplier tube have shown that, for photon wavelengths of 455 nm, 515 nm and 625 nm, the maximum initial energies of the emitted photoelectrons are approximately 0.3 eV, 0.2 eV and 0.1 eV respectively. Combining these experimental results with simulations performed using the SIMION simulation package, a compact radio-frequency photoelectron multiplier tube with a temporal resolution better than 10 ps is proposed. The device would be suitable for applications in several fields, particularly in medical optical instruments employing time-correlated single-photon counting.

Fields of Study & Subjects

Photocathodes and Microchannel Plates Radiation Detection and Scintillator Technologies Particle Accelerators and Free-Electron Lasers

Publication details

Journal / source
Journal of Instrumentation
Publisher
IOP Publishing
Volume
21
Issue
06
Pages
C06007–C06007
Publication date
1 June 2026
Language
EN