Abstract Passive cooling strategies are central to achieving thermal comfort in Malaysia’s hot-humid climate, yet their application in contemporary affordable housing remains inconsistent. This study compares the environmental performance of a traditional Malay timber house (Rumah Kutai Tiang 12) with a modern Rumah Selangorku unit by using Computational Fluid Dynamics (CFD) simulations to examine airflow behaviour, indoor temperature, and relative humidity patterns. Although both prototypes maintained moderate thermal conditions (approximately 25–27 °C), the vernacular house displayed substantially greater ventilation rates, attributed to its elevated floor, larger openings, and lightweight envelope. The modern unit’s higher thermal mass and reduced façade permeability restricted air circulation and moisture dissipation. The analysis demonstrates that vernacular design strategies remain highly effective for enhancing indoor environmental quality and should be considered in the development of contemporary social housing.