A methodology for evaluating MEMS switch reliability at cryogenic temperatures

Read full text
Authors: Elizabeth Sorenson, Peter Bradley, Damian Lauria, Li‐Anne Liew
Cited by: 1
References: 6

Abstract

Abstract Current commercially available Micro Electromechanical Systems (MEMS) switches are designed to operate within a limited range of temperatures near room temperature, thus their long-term performance at lower temperatures requires more investigation. We developed a set of reliability test methods for MEMS at cryogenic temperatures. We demonstrate measurements of the commercial MEMS switches’ hysteresis curve widths, contact resistances, and switching times, at up to ten equilibrium temperatures from room temperature down to 18K. We also performed these characterizations as a function of the number of switching cycles, for up to 1 million cycles at temperatures of 18K and 50K. These test methods may potentially help provide MEMS manufacturers and users with data for device development, and for developing guidelines for MEMS cryogenic applications.

Fields of Study & Subjects

Advanced MEMS and NEMS Technologies Mechanical and Optical Resonators Force Microscopy Techniques and Applications

Publication details

Journal / source
IOP Conference Series Materials Science and Engineering
Publisher
IOP Publishing
Volume
1344
Issue
1
Pages
012120–012120
Publication date
1 April 2026